📦 Download this project here.
A UR5e arm with a four-finger soft pneumatic gripper picks an apple, a tomato and a pear from a table and places each one in a tray. Air pressure bends the fingers, and the bending changes the chamber volume, which changes the pressure again. All of this is modelled physically in Simscape™, with no FEM and no lookup-table actuator. The finger is validated against published hardware data.
The Unreal Engine® replays are drawn from the logged simulation only. The 3D scene has no path back into the physics.
What this example shows you
- How to model a soft actuator in Simscape Multibody™: an 8-hinge pseudo-rigid-body finger, coupled to a Simscape gas network through one Rotational Mechanical Converter per chamber.
- How to identify the finger from a published force table and check it against the paper's other measurements: free bend, grasp force and hold pressure.
- How to close the loop with a Stateflow® pick controller that checks the grasp using only the fingers' bend sensors.
| Product | Used for |
|---|---|
| MATLAB® | Scripts, parameters, the offline finger model |
| Simulink® | Closed-loop model |
| Simscape™ | Gas network: regulator, manifold, finger chambers |
| Simscape™ Multibody™ | Finger hinges, fruit, contact forces, UR5e arm |
| Stateflow® | Pick controller |
| Robotics System Toolbox™ | UR5e model (loadrobot), inverse kinematics, Simulation 3D Robot block |
Optional
| Product | Used for |
|---|---|
| Simulink® 3D Animation™ | Unreal Engine replay and the GIFs (playSoftGripperPick) |
| Optimization Toolbox™ | Re-identifying the finger from the data (fit_zhu_finger_prb, plotSoftGripperFigures) |
R2026b is needed for the JointConfiguration port of the Simulation 3D Robot block used by the replay.
Open MATLAB in this folder, then:
runSoftGripperExample % simulate one pick, score it against the requirements, replay it in 3DTo call any other script directly, run setupSoftGripperExample once per session first. It puts the code
folders on the path (runSoftGripperExample does this for you).
| What | Command | Time |
|---|---|---|
| Replay a saved pick only (no simulation) | playSoftGripperPick(3) (3 apple, 4 tomato, 5 pear) |
~1 min |
| Close-up replay of the grasp | playSoftGripperPick(3, 30, "close") |
~1 min |
| Full closed-loop pick | runSoftGripperExample (set objId; doSimulate = false to replay only) |
22–32 min for 5.7–7.2 s simulated |
| Finger free-bend check vs the paper | check_softgripper_finger("T-F1") |
~80 s |
| Finger force check, 29 points | check_softgripper_finger("T-F2") |
~4.5 min |
| README figures | plotSoftGripperFigures |
seconds |
The shipped results/pick_3|4|5.mat are replay copies (five signals, resampled to 200 Hz). Running a pick
overwrites them with the full log. No script changes a model file; every parameter goes in through
Simulink.SimulationInput.
flowchart LR
subgraph Controller["Controller (Stateflow, 5 ms)"]
Plan["Offline plan<br/>IK waypoints +<br/>minimum-jerk segments"] --> Task["PickTask<br/>approach · close · check grasp<br/>lift · carry · lower · release<br/>retry ≤ 3, timeout 15 s"]
end
subgraph Plant["Plant (Simscape)"]
Arm["UR5e<br/>(kinematic)"] --> Grip["Gripper<br/>4 × SoftFinger"]
Gas["GripperGas<br/>ITV101x regulator<br/>+ manifold"] -- "air, 4 ports" --> Grip
Grip -- "contact" --> Fruit["ObjectBody<br/>6-DOF ellipsoid"]
end
Task -- "qArmCmd" --> Arm
Task -- "pGripCmd" --> Gas
Plant -- "qArmMeas · pGripMeas · bendMeas" --> Task
Plant -. "zTruth (logging only)" .-> Log[("results/ + 3D replay")]
The controller sees only what a real gripper could measure: arm joint angles, manifold pressure and one bend
sensor per finger. Contact forces, fruit pose and slip are truth signals. They are logged for scoring and
the replay, and a structural check (verify_softgripper_hierarchy) proves that none of them reaches the
controller.
| Top level: controller ↔ plant | Plant |
|---|---|
![]() |
![]() |
Each finger (SoftFinger.slx) is a chain of 8 Hinge.slx references, one per chamber of the real finger.
In every hinge, a Rotational Mechanical Converter (G) turns chamber pressure into hinge torque and hinge
rotation into chamber volume. That two-way coupling is what makes the finger soft: a blocked finger
compresses its own air.
Hinge.slx: one chamber |
SoftFinger.slx: 8 hinges in series |
|---|---|
![]() |
![]() |
Per hinge i, with the pressure p acting above a pre-stretch dead zone p0:
K θi + K3 θi3 = D max(p − p0, 0) + Mcontact,i V = V0 + D Σθi
L = 105 mm, D, K, K3 and p0 are identified from Zhu et al. Table 1, because the
paper publishes none of them (fit_zhu_finger_prb.m). The cubic term models silicone stiffening as it
stretches.
Air supply: GripperGas.slx |
Pick controller: PickTask chart |
|---|---|
![]() |
![]() |
The regulator is an SMC ITV101x-class proportional valve: a PI loop on the manifold pressure with clamping anti-windup, and supply and exhaust valves sized from the catalogue flow curve via ISO 6358. One manifold feeds all four fingers through 2 mm ports.
The finger is validated against Zhu et al., Sensors 22:4532 (2022). "Component" checks run one part on its own test bench; "integrated" checks run the whole gripper on a bench, without the arm.
| Check (stage) | Model | Hardware / prediction | Limit | Result |
|---|---|---|---|---|
| Tip force, Zhu Table 1, 29 points (component) | RMS 0.050 N, max 0.127 N | measured | RMS ≤ 0.08 N | ✅ |
| Free bend at 40 / 50 / 60 kPa (component) | 81 / 94 / 104° | 75 / 90 / 110° | ± 10° | ✅ |
| Sealed finger obeys the gas law, +10° bend (component) | 35.61 kPa | 35.62 kPa, adiabatic pVγ | 1 % | ✅ |
| Fill time 0 → 95 % of 60 kPa (component) | 17.7 ms | 17.3 ms, nozzle prediction from the valve catalogue | ± 10 % | ✅ |
| Enveloping grasp force, Zhu Table 3, 30–60 kPa (integrated) | 1.64 / 3.30 / 5.40 / 7.51 N | 2.28 / 3.47 / 4.68 / 5.80 N | ± 30 % | ✅ 4/4 |
| Minimum hold pressure, Zhu Table 4 (integrated) | apple 34, tomato 34, pear 44, mango 60 kPa | 30 / 35 / 45 / 60 kPa | ± 10 kPa | ✅ 4/4 |
How to read the table:
- Free bend. The 75° and 90° are where Table 1's tip force reaches zero, so they are upper bounds, and they are part of the fitted data. The model bends 6° and 4° past them; at 60 kPa it bends 104° against the 110° in the paper's abstract.
- Gas law and fill time check the Simscape build against theory and the valve catalogue, not against the finger hardware.
- Hold pressure holds each fruit where the pick grips it and loads it with its weight plus a 2 m/s² transport acceleration, so it is a stricter test than a static hold.
The Simscape finger reproduces the offline identification to 0.0000 N at all 29 points. The remaining gap to
the data lies in the identified model itself (8 hinges, and an assumed gauge direction the paper does not
state), not in the Simscape build. Full pass/fail per requirement:
docs/soft-gripper-verification.md.
The pressure ramps to 45 kPa over 0.3 s and the four bend sensors rise together. The controller declares a grasp once all four bend sensors have stopped moving and at least 3 fingers sit short of their free-bend angle, because the fruit is in the way. During the carry, a drop detector watches for 2 or more fingers bending further. One short impact peak (15.6 N) stays well under the apple's 40 N bruise limit. Then the arm lifts, carries and lowers the apple, and venting releases it into the tray.
| Fruit | Grip pressure | Release starts over the tray | Attempts | Slip in the grip (≤ 5 mm) | Peak contact / bruise limit |
|---|---|---|---|---|---|
| Apple 200.6 g | 45 kPa | 5.21 s | 1 | 0.9 mm | 15.6 / 40 N |
| Tomato 282.9 g | 39.2 kPa | 5.21 s | 1 | 1.1 mm | 10.5 / 11 N |
| Pear 389.1 g (lying) | 60 kPa, lift at 1 m/s² | 5.72 s | 1 | 1.3 mm | 26.3 / 40 N |
Slip is the largest movement of the fruit relative to the gripper between lift-off and release.
Every controller value (sample time, closing ramp, grasp-check thresholds, per-fruit pressure) is derived in
docs/rationale.md.
- Pressure 30–60 kPa. Below about 30 kPa the fingers do not reach the fruit: the identified pre-stretch dead zone is 13 kPa, and the fingers stand on a 60 mm radius (120 mm between opposite fingers).
- Fruit about 70–110 mm across. A raspberry or cherry tomato (20–30 mm) cannot be grasped with this mounting: the fingers sweep past it on a table, and when it hangs from a stem they push it up and break the stem.
- The mango (580 g) is beyond the 60 kPa finger rating while moving. It is modelled but not picked.
- The arm is kinematic. It follows its joint commands exactly; there are no arm dynamics or joint controllers.
- Fingertip grasp force (Zhu Table 3) cannot be checked: the paper does not say where the test ball sat, and the result changes ×7 over 20 mm of ball height.
- Estimated, not measured: finger mass and damping, contact stiffness and damping, friction, dead volume, scene layout. The tomato's 5 % bruise margin depends on the damping estimates.
- Not verified: low friction, a leaking finger, supply droop (REQ_GRIP_024–026), robustness sweeps.
- Load the fingers too, not only the fruit. In a moving pick the soft fingers carry their own inertia and open. The grip benches therefore use an effective gravity g − agripper that loads fingers and fruit together; a bench that loads only the fruit overestimates the grip.
- Build what you identified, and test it the way it was measured. Under the force gauge the identified finger takes an S-shape with slightly negative base angles, so the Simscape hinges have no end stop. The tip sits in a prismatic "gauge slide" that holds its angle as in the experiment; a frictionless plate lets it slide off.
- How you test hold pressure matters. Closing at full pressure and then lowering it measures release. A grasp formed at the working pressure holds less, and the grip pressures here use that second method.
- Closing speed is a design parameter. A 0.1 s pressure ramp gives impact spikes above the bruise limits (tomato 18.7 N, pear 46.5 N); 0.3 s keeps them below.
- Watch the solver. With zero-crossing detection on the regulator's valve limits, the step shrinks to 2e-6 s and a pick stalls. With it off, a pick runs in about 23 minutes. The limits are only kinks that the variable-step solver crosses accurately.
| To change | Edit | Then re-run |
|---|---|---|
| Your finger's force data | the table in fit_zhu_finger_prb.m, then fit_zhu_finger_prb(8, "cubic") → copy L, D, K, K3, p0 into params_softgripper_finger.m |
check_softgripper_finger (T-F1, T-F2, T-F3) |
| Number of chambers / fingers, mounting radius | finger.N_Joint, finger.n_Fingers, finger.r_Mount |
finger and grasp checks |
| Regulator, tubing, volumes | params_softgripper_gas.m (catalogue flow Q_ANR, p_GripMax, d_Tube, V0) |
check_softgripper_gas |
| Objects: shape, mass, bruise limit, friction | params_softgripper_objects.m |
check_softgripper_objects, check_softgripper_hold |
| Grip pressure, timing, grasp check | params_softgripper_ctrl.m, with a row in docs/rationale.md |
runSoftGripperPick |
Re-run the checks in the order of the table: component first, then integrated, then the closed loop. This is the validation order the example follows.
| Path | Contents |
|---|---|
runSoftGripperExample.m |
Start here. setupSoftGripperExample.m puts the folders below on the path |
models/ |
SoftGripperPick.slx (closed loop: controller + plant); components SoftFinger, Hinge, GripperGas, ObjectBody, UR5eArm (Subsystem References); SoftGripperScene3D.slx (Unreal replay) |
benches/ |
Component and integrated test benches: FingerBench*, GasBench, ObjectBench, GripperBench, with their parameter and run helpers |
params/ |
params_softgripper_*.m: every parameter, each with unit and source; fit_zhu_finger_prb.m: finger identification |
checks/ |
check_softgripper_*.m, verify_softgripper_hierarchy.m: validation tests, resumable, with an evaluate-only mode |
pick/ |
One closed-loop pick: planSoftGripperPick, runSoftGripperPick, scoreSoftGripperPick |
replay/ |
playSoftGripperPick and helpers (Unreal replay, GIFs); plotSoftGripperFigures (README figures) |
docs/ |
rationale.md (every controller value); verification results; object properties and sources |
results/ |
Saved picks (replay copies) |
images/ |
GIFs, figures, model screenshots, replay meshes |
- Zhu, Feng, Hua, Wang, Hu, Wang, Su, Sensors 22(12):4532, 2022,
doi:10.3390/s22124532 (open access,
PMC9230056): finger geometry, Tables 1–4. © 2022 the
authors, CC BY 4.0. The table values are used in
fit_zhu_finger_prb.mand the checks, and plotted infinger_validation.png; the figure is our own. - SMC ITV1000-series electro-pneumatic regulator catalogue: flow and accuracy.
- UR5e model from Robotics System Toolbox™ (
loadrobot("universalUR5e")).
This is a how-to example, not a research result. The fruit properties are partly estimated (see
docs/soft-gripper-object-sourcing.md).