Node-RED Integration Guide — Expert Amp Server

A project-shareable Node-RED example flow for Expert Amp Server. This guide covers the example flow included at docs/integrations/node-red-example-flow.json.


Overview

The example flow is a dashboard-fidelity port of the WB2WGH SPE Linear flow (V1.3). It preserves the original layout, CSS, button styles, gauge and level widgets, and color-state logic, while rewiring all reads and writes from serial to the Expert Amp Server /api/v1 API. Live status is websocket-first via /api/v1/status/ws, with HTTP polling retained as an automatic fallback path.

Thanks to Ron, WB2WGH, for publishing the original SPE Linear Node-RED flow that this version is based on. Reference announcement for the version used here: https://groups.io/g/nodered-hamradio/topic/expert_spe_linear_flow/116437717

Required Node-RED packages:

  • node-red-dashboard
  • node-red-contrib-ui-level
  • core Node-RED websocket nodes (built in; no extra install)

Install via the Node-RED palette manager or:

cd ~/.node-red
npm install node-red-dashboard node-red-contrib-ui-level

What the flow does

Live status + fallback

Path Mode Interval / behavior Endpoint
Primary live status WebSocket Connect once, receive initial snapshot + change-driven updates GET /api/v1/status/ws
Fallback status HTTP poll Every 5 s only while websocket is down GET /api/v1/status
Alarms HTTP poll Every 10 s GET /api/v1/alarms

Dashboard groups (tab: "Expert Amp")

Group Width Purpose
Display 12 Expert Amp display render image (/api/v1/display/render.png)
SPE 6 Main telemetry tiles + gauges + levels
SPE Auxiliary 4 Front-panel control buttons

SPE group tiles (order matches original WB2WGH flow exactly)

Order Tile Type Width Notes
1 Model status tile 2 Read-only; shows model name
2 ATU SWR ui_level 4 Driven from status.swr
3 RX/TX status tile 2 Green = Receive, Red/Yellow = Transmit
4 ANT SWR ui_level 4 Driven from status.antennaSwr, falling back to status.swr
5 Mode action tile 2 Green = Standby, Red = Operate; click sends operate
6 Output Power ui_level 4 Driven from status.powerWatts (scaled 0–100%) when present
7 PWR Level status tile 2 Color-coded by level + mode state
8 Power W gauge ui_gauge 2×2 0–1500 W
9 SWR gauge ui_gauge 2×2 1–3
10 Antenna action tile 2 Click cycles antenna; shows status.antenna
11 Input action tile 2 Click cycles input; shows status.input
12 PA Volts gauge ui_gauge 2×2 0–60 V, driven from status.paSupplyVoltage
13 PA Amps gauge ui_gauge 2×2 0–60 A, driven from status.paCurrent
14 Bank status tile 2 Read-only; shows antennaBank (bank select not in current API)
15 Tune action tile 2 Static green; sends tune
16 Temp Lower / Comb gauge ui_gauge 2×2 0–120 °C, prefers lower/combiner status fields and falls back to upper temp
17 Logging State badge 2 Shows "HTTP API" (file logging removed)
18 Band status tile 2 Read-only; shows status.band
19 RX Antenna status tile 2 Read-only; shows antenna + bank
20 Warnings status tile 3 Blue = No Warnings, Orange = Warning present
21 Alarms status tile 3 Blue = No Alarms, Red = Alarm active
22 Power On orange button 2 Calls experimental POST /api/v1/actions/wake
23 USB Status status tile 1 Green = websocket live, Orange = HTTP fallback, Red = API error
24 USB Sync action tile 1 Triggers immediate HTTP refresh
25 Power Off orange button 2 Sends off action

SPE Auxiliary group buttons (order matches original exactly)

Order Button Action sent
1 Backlight Off backlight-off
2 Backlight On backlight-on
3 L - l-
4 L + l+
5 C - c-
6 C + c+
7 Band - band-
8 Band + band+
9 Set set
10 Display display
11 Left Arrow left
12 Right Arrow right
13 Fan Boost Requests persistent CONTEST mode through POST /api/v1/fan-policy/override
14 Fan Normal Requests persistent Normal mode through POST /api/v1/fan-policy/override

Configuration

Edit the "Set expertAmpBaseUrl" function node to point at your server:

const baseUrl = 'http://amp-host.local:8088';  // your host

Default is http://localhost:8088.

Clean-import gotcha: the three ui_level nodes require their full node-red-contrib-ui-level configuration. If Node-RED logs Cannot read properties of undefined (reading 'indexOf') from ui-level.js, the flow was imported from a damaged or hand-edited export with incomplete level-node fields. Re-import the checked-in flow and verify node-red-contrib-ui-level is installed.

Also update the websocket-client config node if your server is not local:

ws://amp-host.local:8088/api/v1/status/ws

Use wss://... if your deployment is TLS-terminated.


Button actions

All buttons POST to POST /api/v1/actions/button with {"name": "<action>"}.

Currently supported actions (safe per transport/buttons.go):

set, left, right, up, down, display
input, antenna, band-, band+
l-, l+, c-, c+
tune, off, power, operate, cat
backlight-on, backlight-off

Intentionally blocked (not in current command table or not safely confirmed):

back, on, standby

Fan mode is not a raw front-panel action. The checked-in dashboard's Fan Boost and Fan Normal buttons POST {"mode":"contest"} or {"mode":"normal"} to /api/v1/fan-policy/override. Check supportedModes first: promoted First Series 1.3K-FA and Second Series 1.5K-FA profiles advertise normal and contest; unsupported models advertise no modes and fail closed before SET. These overrides remain active until explicitly changed unless an API client supplies durationMinutes; that countdown begins only after the requested mode is display-verified. Send {"mode":"automatic"} to return desired-policy selection to the temperature controller.

Production fan control supports the promoted First Series Expert 1.3K-FA and CONFIG-first Second Series Expert 1.5K-FA model-bound topologies after physical apply/restore verification on both models. Unsupported models are blocked before SET; F-KFA NORMAL/QUIET layouts remain topology-only.

The original WB2WGH macro is not safe to reproduce through generic button calls. It was fan-tested only on a 2K-FA, sends a fixed eleven-RIGHT menu sequence without reading the LCD, and can alter the wrong setting if the starting screen or one command differs. The server replaces it with the captured display-verified transaction.

Do not replace that macro with another blind sequence, including a 13-command Expert 1.5K-FA flow. Use the built-in Menu Debug wizard or its guarded API: one start runs discovery and apply automatically, but each command remains separately authorized and blocked until a newer matching LCD receipt arrives. The wizard then waits for physical candidate confirmation before automatic restore and waits again for confirmation that the original value returned. Incomplete diagnostics are visible and downloadable in the token-bearing built-in UI; they are never uploadable promotion evidence.

Use GET /api/v1/fan-policy for the disabled-by-default temperature/hysteresis decision and navigation receipt. Production control requires a promoted model profile and supports the verified First Series Expert 1.3K-FA and CONFIG-first Second Series Expert 1.5K-FA paths; unsupported models are blocked before SET. Active control requires polling mode both and starts only after fresh protocol and checksum-valid LCD RX evidence. The server verifies the model plus first SET-menu topology and then every waypoint. If initially OPERATE, it temporarily requests and verifies STANDBY because tested hardware ignores SET on the OPERATE home screen. After verified SAVE and return home it restores and verifies OPERATE only when this transaction originally disabled it.

If TX begins, the controller sends no writes, pauses its ordinary waypoint timeout, and resumes only after ordered protocol and LCD RX evidence reverifies the exact expected state. Fan-value toggles and SAVE are RX-only. The temporary STANDBY may skip an unattended transmit cycle. Overtemperature safety preempts fan control and suppresses OPERATE restoration. After stale or unknown status, unsupported state, timeout, ambiguous toggle, write failure, or screen mismatch, the controller never blindly restores OPERATE and requires the operator to verify STANDBY.

Failed navigation responses include the original navigation.lastError and navigation.recoveryInstructions; the checked-in flow prints both instead of replacing them with only the generic latch error. To recover, stop transmitting, put the amplifier in STANDBY, use the physical panel to return home, disable automatic fan-policy switching, and wait for fresh STANDBY/RX home evidence. Then use Clear Failed Fan Transaction in the built-in Settings page or POST /api/v1/fan-policy/recover. Recovery sends no amplifier command, clears the failed manual override, and does not restore OPERATE.

POST /api/v1/fan-policy/verify refreshes a receipt loaded as persisted-stale after server restart. While connected, a complete manually driven FAN MANAGEMENT → SAVE → STORING DATA → home sequence is also observed and recorded. A menu value seen before SAVE is never treated as the stored EEPROM mode.


Preserved vs changed from original WB2WGH flow

Preserved

  • SPE Master CSS — all original classes intact: SPEvibrate, SPEfilled, SPEtouched, SPErounded, SPEhoverblue, SPEhoverred
  • Group layout — SPE (width=6) and SPE Auxiliary (width=4) on one dashboard tab
  • All 25 SPE tile names and order — identical to the original
  • All 14 SPE Auxiliary button names and order — identical to the original
  • ui_gauge ×5 — same positions (orders 8, 9, 12, 13, 16) and 2×2 size
  • ui_level ×3 — ATU SWR, ANT SWR, Output Power at orders 2, 4, 6
  • Color-state logic — RX/TX, Mode, PWR Level, Warnings, Alarms use same gradient rules
  • Tune static-green button — preserved
  • Power On / Power Off orange buttons with SPEhoverred hover style

Changed

Original This flow Reason
Serial port nodes Websocket-first status via /api/v1/status/ws with HTTP fallback to /api/v1/status No direct serial in Node-RED
USB status = physical USB USB Status = websocket/API connectivity state Serial path removed
USB Sync = serial resync USB Sync = immediate HTTP refresh Rewired to API transport
Logging State = CSV file Logging State shows "HTTP API" File logging not applicable
Gauge labels: Volts / Amps Gauge labels now use promoted API fields for PA volts and PA amps Driven from /api/v1/status instead of hidden note strings
Bank select buttons Bank tile is read-only Bank select not in current API
Fan Quiet / Fan Normal Fan Boost / Fan Normal use the verified fan-policy override API Raw fan buttons are not document-backed commands; the server performs the captured temporary-STANDBY transaction
Backlight On/Off Document-backed backlight-on / backlight-off actions Hardware effect remains model-dependent
Power On (Python script) Calls experimental POST /api/v1/actions/wake Experimental HTTP wake action
History charts / fidelity notes Removed from the example They added clutter and unnecessary dashboard weight for the current use case

Added (not in original)

  • Display render image at top (Expert Amp Server feature, per project direction)

Smoke-test checklist

Before declaring the flow healthy:

  1. Server reachable — deploy, open Node-RED debug panel, confirm base URL message on startup
  2. Websocket/fallback status works — confirm tiles update. USB Status should show green WS Live when websocket messages are flowing, or orange HTTP Fallback when the fallback poll path is active.
  3. Fallback recovery works — interrupt websocket/server access; USB Status should turn red on API errors, then return to WS Live or HTTP Fallback after connectivity is restored.
  4. Tiles update — open Node-RED Dashboard (/ui), confirm SPE tiles show values
  5. Display render loads — Display group shows amp display image (may be blank in fixture mode)
  6. Safe button action works — click Set or Display button; check debug tab for OK: set / OK: display
  7. Alarm tile updates — /api/v1/alarms returns protocol-native warning/alarm lists plus safety-monitor state. Monitoring is observational unless the server's separate overtemperature standby arm flag is explicitly enabled; with no active vendor alarm, Warnings + Alarms should show blue No Alarms / No Warnings
  8. Error handling — stop the Expert Amp Server completely; USB Status tile should turn red after fallback requests fail

Required packages

Package Purpose
node-red-dashboard Core dashboard nodes like ui_template, ui_gauge, ui_chart, ui_group, ui_tab
node-red-contrib-ui-level Provides the ui_level nodes used for ATU SWR, ANT SWR, and Output Power bars

If import complains about unrecognized ui_level node types, this second package is the missing dependency.

The websocket nodes used here are part of core Node-RED; no extra websocket package is required.


Notes

  • Websocket-first design for live status, with automatic HTTP fallback so the dashboard does not go stale on disconnect.
  • Flow works against the canonical /api/v1 surface. No direct serial wiring in Node-RED.
  • /api/v1/status/ws carries the same canonical status model as GET /api/v1/status and is the preferred live feed.
  • Stable automation fields include outputLevel as a string and temperatureC as a JSON number in canonical Celsius. For example, a Node-RED function can use String(status.outputLevel || '') for the power preset and Number(status.temperatureC) only after checking that the field is present. Do not parse temperatureDisplay for automation.
  • /api/v1/status remains the fallback polling route and the authoritative machine-readable status surface for reconnect gaps and manual refreshes. It uses the vendor-documented status poll/response shape where available, with display-derived values only as fallback. Protocol-backed fields now include raw-plus-decoded band and warning/alarm fields (bandCode/bandText, warningCode/warningsText, alarmCode/alarmsText), the raw atuStatusCode, and first-class meter fields such as antennaSwr, paSupplyVoltage, paCurrent, temperatureLowerC, and temperatureCombinerC when the amp model reports them. All *C fields are canonical Celsius; set amplifierTemperatureUnit to match the amplifier SET menu because the status response itself omits the unit.
  • The checked-in example intentionally matches the cleaned-up working dashboard: no History group, no extra chart panels, and a tighter display block.
  • All node IDs are stable across re-imports (MD5 of seed name). Existing nodes will update on re-import.
  • The flow is project-clean: no Ian-specific hostnames, entity IDs, or HA-specific details.